Overview of the machine:
Industrial Pharmaceutical Machine Automatic Capsule Filler High Quality Capsule Filling Machine
The NJP-800 series capsule filling machine designed and produced by our factory has been improved and innovated for many times, and is the preferred equipment for hospitals and small and medium-sized pharmaceutical factories, replacing the original semi-automatic capsule filling equipment.
The whole machine adopts intermittent rotary mechanism and quantitative filling. Suitable for 00 # -5 # capsule powder and capsule filling, and can be equipped with automatic bag delivery machine, vacuum feeding machine, gold inspection machine, polishing machine, hoist and other auxiliary equipment.
Technical parameters:
Output | 800Capsules/min |
No.of segment bores36 | 6 |
Suitable fof capsule | 00#-5# |
Total power | 4.5Kw(Standard configuration) |
Overall weight90 | 1000Kgs |
Overall diemensions | 840(+339)mm×820(+339)mm×2000m |
Noise | ≤75DB(A) |
Pressure | 0.4 ~ 0.7Mpa |
Air consumption | ≤6m³ |
Vacuum | -0.03 ~ -0.06Mpa |
Filling error | ±2.5%~±5% |
The machine may make technical improvements without prior notice, and the attached picture shows the options that may be offered.
Filling-type metering filling:
A-f represents the punching rod of each group, during the interval after the interval time the angle. The powder in the measuring plate mold hole is compacted by each group punching rod once. When the charging rod is lifted from the die hole, the powder box rotates, and the powder on the metering plate will automatically fill the remaining space in the die hole. Fill once, compaction once, until the sixth time, the punching rod will poke the powder column in the mold hole out of the measuring plate, so that it will fall into the empty capsule below, complete the filling work.
Use the relative movement between the scraping powder block and the measuring plate to scrape the excess powder on the surface of the measuring plate to ensure the measurement requirements of the powder column.
The characteristics of the packing-type measurement method
1. The loading amount is accurate, and the difference of the loading amount of> 0.3g is controlled within ± 3%.
2. Adjust the lifting height of the punching rod to fine-tune the dose of drug filling.

Rejection station:
Use Some empty capsules may keep the body cap still for some reason, and remain in the upper module hole; to prevent mixing into the finished product, they are removed before the capsule is closed. Principle A push hand that can reciprocate up and down, located between the upper module and the lower module, with a thimble hand. When the upper and lower modules rotate, the push hand stops at the lower limit position and the thimble breaks away from the upper module. When the module stops at this station, the push hand goes up and the thimble mounted on the push hand is inserted into the upper module hole. ①. If there is a pulled out capsule cap in the upper mold hole, the upward top has no impact on the capsule cap. ②. If there is an open empty capsule in the upper mold hole, the upper module is pushed out by the upward thimble and sucked into the air chamber. |  |
Three-dimensional adjustment mechanism:
1.Eliminate the metering plate, copper ring natural deformation degree, uniform clearance, reduce the phenomenon of powder leakage;
2.Easy to disassemble and disassemble, easy to clean;
3.Ensure device differences.