Technical parameters:
Output | 1200Capsules/min |
No.of segment bores3 | 3 |
Suitable fof capsule | 00#-5# |
Total power | 5.6Kw(Standard configuration) |
Overall weight90 | 900Kgs |
Overall diemensions | 760(+304)mm*780mm(+304)*1900mm |
Noise | ≤75DB(A) |
Pressure | 0.4 ~ 0.7Mpa |
Air consumption | ≤6m³ |
Vacuum | -0.03 ~ -0.06Mpa |
Filling error | ±2.5%~±5% |
The machine may make technical improvements without prior notice, and the attached picture shows the options that may be offered.
Rejection station:
Use Some empty capsules may keep the body cap still for some reason, and remain in the upper module hole; to prevent mixing into the finished product, they are removed before the capsule is closed. Principle A push hand that can reciprocate up and down, located between the upper module and the lower module, with a thimble hand. When the upper and lower modules rotate, the push hand stops at the lower limit position and the thimble breaks away from the upper module. When the module stops at this station, the push hand goes up and the thimble mounted on the push hand is inserted into the upper module hole. ①. If there is a pulled out capsule cap in the upper mold hole, the upward top has no impact on the capsule cap. ②. If there is an open empty capsule in the upper mold hole, the upper module is pushed out by the upward thimble and sucked into the air chamber. | ![]() |
Locking station:
Use Lock the capsule of the push rod to meet the requirements of the finished product. Principle The upper and lower modules are rotated to the lock, when the axis of the upper and lower modules overlap. The upper baffle above the module begins to move against the top bar below. The upper baffle presses the capsule cap, the top rod rises, and the capsule cap body is closed and locked | ![]() |
Finished capsule discharge station:
Use The finished capsules will be pushed out for collection. Principle The main component of the device is a discharge top rod that can reciprocate up and down. When the upper and lower modules carrying the closed capsule are rotated above the exit station and stopped, the capsule is pushed out of the module hole. The capsule was then blown into the outgoing hopper and slid into the stock barrel. | ![]() |
Cleaning station:
Use The cleaning unit cleans the module for access to the next cycle. Principle When the upper and lower modules are dragged under the main working plate and parked at the cleaning station, they are placed at the gap of the cleaning device. At this time, the compressed air is opened, and the powder in the mold hole and the broken skin are blown out of the mold hole from the lower direction of the lower module. The vacuum suction system placed above the mold hole draws it into the vacuum cleaner to keep the mold hole clean and to facilitate the next cycle operation. | ![]() |